1. [1]張宇嬌,郭梽炜,汪振亮,等.基于電磁場—流場—溫度場耦合分析的電纜支架溫升計算及 實驗驗證[J].高壓電器,2019,55(08):143-148,156.[doi:10.13296/j.1001-1609.hva.2019.08.020]
             ZHANG Yujiao,GUO Zhiwei,WANG Zhenliang,et al.Calculation and Experimental Verification of Cable Support’s Temperature Rise Based on Electromagnetic-fluid-thermal Fields[J].High Voltage Apparatus,2019,55(08):143-148,156.[doi:10.13296/j.1001-1609.hva.2019.08.020]
            點擊複制

            基于電磁場—流場—溫度場耦合分析的電纜支架溫升計算及 實驗驗證()
            分享到:

            《高壓電器》[ISSN:1001-1609/CN:61-11271/TM]

            卷:
            第55卷
            期數:
            2019年08期
            頁碼:
            143-148,156
            欄目:
            研究與分析
            出版日期:
            2019-08-15

            文章信息/Info

            Title:
            Calculation and Experimental Verification of Cable Support’s Temperature Rise Based on Electromagnetic-fluid-thermal Fields
            作者:
            張宇嬌 郭梽炜 汪振亮 黃雄峰 智 李
            (三峽大學梯級水電站運行與控制湖北省重點實驗室, 湖北 宜昌 443002)
            Author(s):
            ZHANG Yujiao GUO Zhiwei WANG Zhenliang HUANG Xiongfeng ZHI Li
            (Hubei Key Laboratory of Cascaded Hydropower Stations Operation & Control, China Three Gorges University, Hubei Yichang 443002, China)
            關鍵詞:
            電纜支架 渦流損耗 電磁場—流場—溫度場 多物理場耦合 支架溫升
            Keywords:
            cable support eddy current loss electromagnetic-fluid-thermal fields multi-physics coupling temperature rise of support
            DOI:
            10.13296/j.1001-1609.hva.2019.08.020
            摘要:
            隨著大長度大截面的電力電纜在隧道的普及,電纜支架因渦流損耗造成的線損、以及發 熱産生溫升形變等問題也日益嚴重。文中采用有限元數值計算方法,以110 kV單相電纜及其鋼 支架爲研究對象,進行了電磁場—流場—溫度場耦合計算。將電磁場計算得到的渦流損耗作爲 溫度場計算的熱源載荷,同時考慮空氣自然對流的散熱方式,從而計算出電纜支架的溫度分布 。最後進行電纜支架溫升實驗,將仿真得到數據和實驗數據進行對比,驗證電纜支架溫升計算 的准確性和有效性。
            Abstract:
            The application of large-length and large-section power cable in cable tunnel leads to the serious line loss caused by eddy current in cable support and the thermal deformation of cable support. Taking 110 kV single-phase cable and its cable support as research objects and adopting the finite element numerical calculation method to calculate its electromagnetic-fluid-thermal coupling field. The eddy current loss calculated by the electromagnetic field is taken as the heat source load in fluid-thermal field, and the heat dissipation mode of the natural convection of the air is considered, thereby calculating the temperature distribution of the cable support. Finally, temperature rise experiment of cable support is conducted,and the simulation data are compared with the experimental one to verify the accuracy and effectiveness of the temperature rise calculation of cable support.

            參考文獻/References:

            [1] 馬國棟. 電線電纜載流量[M]. 北京:中國電力出版社,2003:149-154. MA Guodong. Wire and cable ampacity[M]. Beijing:China Electric Power Press,2003:149-154.
            [2] 蒲麗娟,遊世良,吳 昊,等. 大截面電力電纜固定金具參數與渦流損耗的數值關 系分析[J]. 高壓電器,2016,52(1):129-135. PU Lijuan,YOU Shiliang,WU Hao,et al. Numerical relationship between metal cleat parameters of large cross-section power cable and eddy current loss[J]. High Voltage Apparatus,2016,52(1):129-135.
            [3] 王雨陽,王永強,王 浩. 一起110 kV電纜終端特殊部位發熱的分析處理[J]. 江蘇 電機工程,2014,33(1):9-10. WANG Yuyang,WANG Yongqiang,WANG Hao. Analysis on terminal overheat of a 110 kV cable[J]. Jiangsu Electrical Engineering,2014,33 (1):9-10.
            [4] BURGESS J J,CAPOZUCCA P. Measurement of cable support pointmotions due to vortex - induced vibrations experiments with avertical towed cable[C]//IEEE Conference Publications. [S. l. ]:IEEE, 1989:1448-1455.
            [5] 韓金華,楊曉輝,王豐華,等. 500 kV電力變壓器直流偏磁損耗特性的仿真研究 [J]. 高壓電器,2015,51(5):40-46. HAN Jinhua,YANG Xiaohui,WANG Fenghua,et al. Simulation study of DC bias loss characteristics of 500 kV power transformer[J]. High Voltage Apparatus,2015,51(5):40-46.
            [6] 張衛純,潘風明,張新根,等. 基于有限元法的電力變壓器金屬結構件損耗分析 [J]. 高壓電器,2013,49(11):55-61. ZHANG Weichun,PAN Fengming,ZHANG Xingen, et al. Power loss analysis for structural parts in transformer based on finite element method[J]. High Voltage Apparatus,2013,49(11):55-61.
            [7] 周 偉,李 岩,井永騰,等. 換流變壓器諧波損耗的計算與分析[J]. 高壓電器, 2012,48(8):18-23. ZHOU Wei,LI Yan,JING Yongteng,et al. Calculation and analysis of harmonic loss in converter transformer[J]. High Voltage Apparatus, 2012,48(8):18-23.
            [8] 邱洪波. 高速永磁發電機轉子渦流損耗優化及對溫度分布影響的研究[D]. 哈爾濱: 哈爾濱理工大學,2014. QIU Hongbo. Research on eddy current loss optimization and temperature distribution in high speed permanent magnet genrator[D]. Harbin: Harbin University of Science and Technology,2014.
            [9] 朱衛光. 電動車輛永磁同步電機轉子永磁體損耗及溫度場研究[D]. 北京:北京理工 大學,2014. ZHU Weiguang. Research on rotor magnet loss and thermal field in permanent magnet synchronous motor for electric vehicles[D]. Beijing:Beijing Institute of Technology,2014.
            [10] 範 龍. 基于Ansys的複合材料電纜支架的仿真分析[D]. 保定:華北電力大學, 2014. FAN Long. Simulated analysis of the composite cable support based on Ansys [D]. Baoding:North China Electric Power University,2014.
            [11] 馬昀濤,李淩睿,朱 萍. 玻璃鋼複合材料電纜支架的應用分析[J]. 河北電力技 術,2013,32(6):29-30. MA Yuntao,LI Lingrui,ZHU Ping. Application analysis on FRP composite material cable bracket[J]. Hebei Electric Power,2013,32(6):29-30.
            [12] WANG Rongguo,LI Haiyan,LIU Wenbo,et al. Surface modification of poly (urea-formaldehyde) microcapsules and the effect on the epoxy composites performance[J]. Journal of Macromolecular Science,Part a:Pure and Applied Chemistry,2010,47(10):991-995.
            [13] 侯靜梅,歐 繁. SMC高分子複合材料電纜支架的性能優勢和應用[J]. 價值工程, 2012,31(32):69-70. HOU Jingmei,OU Fan. The performance advantages of SMC cable support[J]. Value Engineering,2012,31(32):69-70.
            [14] 朱景林. 電纜支架渦流損耗的研究[J]. 上海電力,2009(5):400-402. ZHU Jinglin. Research of cable eddy current losses[J]. Shanghai Electric Power,2009 (5):400-402.
            [15] 聶永峰,王建輝,孟 毓. 輸電電纜支架渦流損耗的計算與分析[J]. 電網技術, 2008,32(1):142-145. NIE Yongfeng,WANG Jianhui,MENG Yu. Calculation and analysis of eddy current losses in girder frame for transmission cables[J]. Power System Technology,2008,32(1):142-145.
            [16] 朗 道. 流體力學[M]. 孔詳言,徐燕候,莊禮賢,譯. 北京:高等教育出版社, 1984:25-30. LANG Dao. Hydrodynamic[M]. KONG Xiangyan,XU Yanhou,ZHUANG Lixian, Translate. Beijing:Higher Education Press,1984:25-30.
            [17] 李秀廣. SF6電流互感器溫度場有限元分析[J]. 高壓電器,2015,51(2):121- 124. LI Xiuguang. Finite element analysis of temperature field in SF6 insulated current transformer[J]. High Voltage Apparatus,2015,51(2):121-124.
            [18] 李 明. 大溫差封閉腔體自然對流數值模擬[D]. 西安:西安建築科技大學,2015. LI Ming. Numerical simulation of large temperature difference natural convection in the enclosed cavity[D]. Xi’an:Xi’an University of Architecture and Technology, 2015.
            [19] 李慶領,楊廣志,李 濤. 水平圓管在大空間內自然對流換熱的實驗與數值分析 [J]. 蘭州理工大學學報,2013,39(2):43-46. LI Qingling,YANG Guangzhi,LI Tao. Experiment on heat exchange with natural convection over horizontal circular pipe in large space and its numeric analysis[J]. Journal of Lanzhou University of Technology,2013,39(2):43-46.
            [20] 陳彥君,李元陽,劉振華. 基于多相流模型的腔體內納米流體自然對流換熱數值模 擬[J]. 上海交通大學學報,2015,49(5):600-607. CHEN Yanjun,LI Yuanyang,LIU Zhenhua. Experiment on heat exchange with natural convection over hoeizontal circularipe in large space and its numeric analysis[J]. Journal of Lanzhou University of Technology,2015,49(5):600-607.
            [21] 張冠生. 電器理論基礎[M]. 北京:機械工業出版社,1989:17-24. ZHANG Guansheng. Basis theory of electric appliance[M]. Beijing: China Machine Press, 1989:17-24.

            備注/Memo

            備注/Memo:
            張宇嬌(1979—),女,博士,教授,博士生導師,研究方向爲電力設備及電磁裝置多物理場耦 合數值分析及機輔設計。 郭梽炜(1992—),男,碩士研究生,研究方向爲電磁及多物理場耦合研究。 黃雄峰(1980—),男,博士,研究方向爲電力設備及電磁裝置多物理場耦合研究、網絡化控制 系統。收稿日期:2019-02-04; 修回日期:2019-04-11 基金項目:國家自然科學基金項目(51577106)。 Project Supported by the National Nature Science Foundation of China(51577106).